City of Eugene
Planning & Development
Building and Permit Services
Permit Number: 25-05106-01
Date: 10/12/2026
Address: 3704 ROCKCRESS RD
Project Description: Landslide repairs & remediation
Application Type:
Commercial
Status:
Issued
Scope of Work:
Retaining Walls
Zoning:
Low-density Residential Zone
Map:
18-03-03-31
Tax Lot:
05000
Subdivision:
Moon Mountain
Addition:
Lot:
50
Block:
Date Received:
07/30/25
# Bedrooms:
0
Commitment Date:
08/28/25
# Dwelling Units:
0
Ready to issue as of:
08/27/26
In Flood Plain:
Project Coordinator:
Erik Swinney
Phone:
541-682-5372
  
Sign Standards:
 
BUILDING CHARACTERISTICS
Construction Types:
5B
Construction Type Comments:
 
OccupancyTypes:
R3
 
Occupancy Type Comments:
U
 
 
 
 
Occupancy Load:
0
Separated Building:
N/A
Fire Sprinklers:
N/A
 
Fire Alarms:
N/A
 
Building Area:
0
Number of Stories:
0
Comment:
 
Floor Areas (sq ft):
Floor
Existing Floor Area
New Floor Area
Total Area
Existing floor area may not be shown.
CONTRACTOR DATA
Type
Contractor
Building
PLI SYSTEMS INC
Plumbing
PRO LANDSCAPE INC
Primary Contact
LAU TYANA
PLAN REVIEW SUMMARY
Plan review data displayed is the most current for each review. The applicant will receive notification of all issues needing additional information after all reviews on a project have been completed. Supplemental Information (SI) can be submitted prior to or after permit issuance. If you have any questions regarding your project, contact EFSwinney at 541-682-5372 or send email to erik.f.swinney@ci.eugene.or.us. Also note that some reviews (i.e., fire alarms, fire sprinklers) are deferred submittals and will be reviewed after original permit(s) have been issued.
Status Definitions
Pending
=
Review has not been started
Review
=
Under review
Waiting
=
Review for individual review has been completed, waiting for a response
External Wait
=
All reviews for project have been completed, waiting for a response
Approved
=
Review has been approved
Information
=
Information only, review not approved
Denied
=
Project cannot be approved as submitted
For information regarding the review of your project or the commitment date for completion of review, please contact your project coordinator, EFSwinney, at erik.f.swinney@ci.eugene.or.us or by phone at 541-682-5372.
Plan Review
Status
Review Completion Date
Project Coordination, Application Submittal
External Wait Time
08/21/25
Pre Issuance Coord, Pre Issuance SI
Approved
09/15/25
Post Issuance Coord, Post Issuance SI
Approved
08/27/26
Building, Application Submittal
Waiting for info
08/13/25
Building, Pre Issuance SI
Approved
09/15/25
Structural, Application Submittal
Waiting for info
08/13/25
Structural, Pre Issuance SI
Approved
09/15/25
Zoning, Application Submittal
Approved
08/05/25
Public Works, Application Submittal
Waiting for info
08/15/25
Public Works, Pre Issuance SI
Information
09/15/25
Public Works, Post Issuance SI
Approved
08/27/26
Fire Marshal, Application Submittal
Approved
08/01/25
Erosion Inspection, Application Submittal
Approved
09/12/25
PERMITS AND INSPECTIONS
Permit Type
Status
 
Issued Date
Expiration Date
Completion Date
 
Building
Finished
09/15/25
09/25/27
10/01/26
 
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
902 Pre Const Natural Res Prot
Approved
09/22/25
VHVallentyne
 
 
108 Foundation
Approved
08/20/26
SEGalbreath
Final site visit. No deficiencies observed. Approval based on submitted special inspection reports and other documentation.
 
118 Framing
Approved
08/20/26
SEGalbreath
Final site visit. No deficiencies observed. Approval based on submitted special inspection reports and other documentation.
 
903 Post Const Natural Res Prot
Approved
08/21/26
VHVallentyne
 
 
199 Final Building
Approved
09/30/26
SEGalbreath
 
Plumbing
Finished
08/27/26
09/25/27
10/01/26
 
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
403 Storm Sewer - Private
Approved
09/28/26
SEKelley
3” sch 40 perimeter piping picking up downspouts and driveway ribbon drain, are connected (connection covered) to 4” CPE out-falling down the hill (N.E.) on north side of erosion fencing. The second 4” CPE pipe is picking up perforated pipe serving the drainage for the recently constructed wall (covered) by the deck, and out-falls near the same location down the hill.
 
399 Final Plumbing
Approved
09/28/26
SEKelley
 
To request an inspection go to https://pdd.eugene-or.gov/BuildingPermits/InspectionLogin.
For more information call 541-682-5283.
FEES
Fees
Total Due
Amount Paid
Paid Date
Amount Due
Building
$3,574.03
$3,574.03
 
$0.00
Building Plan Check per Applicant Value
$972.30
$972.30
09/15/25
$0.00
Supplemental Plan Review, Bldg
$460.00
$460.00
09/23/25
$0.00
Building Permit Fee per Bldg Div Value
$1,495.84
$1,495.84
09/15/25
$0.00
Zoning Inspection
$115.00
$115.00
09/15/25
$0.00
State Surcharge, Structural
$196.14
$196.14
09/15/25
$0.00
Building Technology Admin Fee, Local
$51.66
$51.66
09/15/25
$0.00
Building Technology Admin Fee, Local
$9.20
$9.20
09/23/25
$0.00
Building Admin Fee, State
$134.63
$134.63
09/15/25
$0.00
Building Plan Check Admin
$87.51
$87.51
09/15/25
$0.00
Building Plan Check Admin
$41.40
$41.40
09/23/25
$0.00
Building Plan Check Admin
$0.00
$0.00
 
$0.00
Building Admin Fee, Local
$10.35
$10.35
09/15/25
$0.00
Plumbing
$213.23
$213.23
 
$0.00
Storm Sewer Footage
$171.80
$171.80
08/26/26
$0.00
State Surcharge, Plumbing
$22.53
$22.53
08/26/26
$0.00
Plumbing Technology Admin Fee, Local
$3.44
$3.44
08/26/26
$0.00
Plumbing Admin Fee, State
$15.46
$15.46
08/26/26
$0.00
Plumbing Plan Check Admin
$0.00
$0.00
 
$0.00
Total All Fees
$3,787.26
$3,787.26
 
$0.00
Page 1 of 1
Date: 10/12/2026