City of Eugene
Planning & Development
Building and Permit Services
Permit Number: 24-05904-01
Date: 11/27/2026
Address: 90201 HWY 99N
Project Description: New metal prefabricated structure.
Application Type:
Commercial
Status:
Issued
Scope of Work:
New Commercial Bldg
Zoning:
Heavy Industrial District
Map:
17-04-04-00
Tax Lot:
02105
Subdivision:
Addition:
Lot:
Block:
Date Received:
08/23/24
# Bedrooms:
0
Commitment Date:
10/19/24
# Dwelling Units:
0
Ready to issue as of:
02/11/25
In Flood Plain:
Project Coordinator:
Erik Swinney
Phone:
541-682-5372
  
Sign Standards:
 
BUILDING CHARACTERISTICS
Construction Types:
2BS
Construction Type Comments:
 
OccupancyTypes:
F1
 
Occupancy Type Comments:
 
unlimited area per OSSC 503.1.1
 
 
Occupancy Load:
0
Separated Building:
N/A
Fire Sprinklers:
N/A
 
Fire Alarms:
N/A
 
Building Area:
210000
Number of Stories:
1
Comment:
mezzanines/equipment platforms/catwalks - 62300 sf
Floor Areas (sq ft):
Floor
Existing Floor Area
New Floor Area
Total Area
Existing floor area may not be shown.
CONTRACTOR DATA
Type
Contractor
Building
WILDISH CONSTRUCTION
Electric
ELECTRICAL PROFESSIONAL SERVICES
Plumbing
WILDISH CONSTRUCTION
Primary Contact
POWELL BILL
PLAN REVIEW SUMMARY
Plan review data displayed is the most current for each review. The applicant will receive notification of all issues needing additional information after all reviews on a project have been completed. Supplemental Information (SI) can be submitted prior to or after permit issuance. If you have any questions regarding your project, contact at or send email to @ci.eugene.or.us. Also note that some reviews (i.e., fire alarms, fire sprinklers) are deferred submittals and will be reviewed after original permit(s) have been issued.
Status Definitions
Pending
=
Review has not been started
Review
=
Under review
Waiting
=
Review for individual review has been completed, waiting for a response
External Wait
=
All reviews for project have been completed, waiting for a response
Approved
=
Review has been approved
Information
=
Information only, review not approved
Denied
=
Project cannot be approved as submitted
For information regarding the review of your project or the commitment date for completion of review, please contact your project coordinator, , at @ci.eugene.or.us or by phone at .
Plan Review
Status
Review Completion Date
Project Coordination, Application Submittal
External Wait Time
10/18/24
Pre Issuance Coord, Pre Issuance SI
Approved
01/14/25
Post Issuance Coord, Post Issuance SI
Approved
11/03/26
Deferred Coordination, Deferred Submittal
Approved
02/19/26
Building, Application Submittal
Waiting for info
09/27/24
Building, Pre Issuance SI
Approved
12/30/24
Building, Post Issuance SI
Approved
10/01/26
Building, Deferred Submittal
Waiting for info
06/06/25
Structural, Application Submittal
Waiting for info
09/24/24
Structural, Pre Issuance SI
Approved
12/18/24
Structural, Post Issuance SI
Approved
11/03/26
Structural, Deferred Submittal
Information
05/27/25
Mechanical, Application Submittal
Information
09/27/24
Mechanical, Post Issuance SI
Waiting for info
11/03/26
Mechanical, Deferred Submittal
Information
06/04/25
Electrical, Post Issuance SI
Approved
05/13/25
Electrical, Deferred Submittal
Approved
02/10/25
Zoning, Application Submittal
Waiting for info
10/11/24
Zoning, Pre Issuance SI
Approved
01/08/25
Zoning, Post Issuance SI
Approved
03/18/25
Public Works, Application Submittal
Waiting for info
10/11/24
Public Works, Pre Issuance SI
Approved
11/25/24
Public Works, Post Issuance SI
Approved
05/28/26
Public Works, Deferred Submittal
Waiting for info
06/04/25
Stormwater Standards, Application Submittal
Waiting for info
10/11/24
Stormwater Standards, Pre Issuance SI
Approved
11/25/24
Stormwater Standards, Post Issuance SI
Approved
03/03/25
SDC, Application Submittal
Waiting for info
10/11/24
SDC, Pre Issuance SI
Approved
11/25/24
SDC, Post Issuance SI
Approved
03/03/25
SDC, Deferred Submittal
Waiting for info
06/04/25
Fire Marshal, Application Submittal
Waiting for info
10/16/24
Fire Marshal, Pre Issuance SI
Approved
11/07/24
Fire Marshal, Deferred Submittal
Approved
02/18/25
Erosion Inspection, Application Submittal
Approved
01/10/25
Fire Sprinkler Plans, Deferred Submittal
Approved
05/15/25
Water Main/Hydrant, Deferred Submittal
Approved
02/19/26
PERMITS AND INSPECTIONS
Permit Type
Status
 
Issued Date
Expiration Date
Completion Date
 
Building
Active
01/10/25
11/14/27
  
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
103 Footing
Reviewed
04/11/25
RZSteiner
See approved plans for highlighted locations.
 
103 Footing
Reviewed
04/25/25
RZSteiner
See highlighted plans for location.
 
103 Footing
Reviewed
05/19/25
RZSteiner
See approved plans for highlighted locations.
 
103 Footing
Reviewed
06/18/25
RZSteiner
See approved plans for highlighted locations.
 
103 Footing
Reviewed
07/14/25
RZSteiner
See approved plans in Ryans office for highlighted location.
 
103 Footing
Reviewed
07/18/25
RZSteiner
See approved plans for highlighted locations.
 
103 Footing
Reviewed
07/24/25
RZSteiner
See approved plans for highlighted locations.
 
103 Footing
Reviewed
08/26/25
RZSteiner
BLDG B See plans for highlighted location.
 
103 Footing
Reviewed
09/04/25
RZSteiner
SOG 14-16 and D-NAJ
 
103 Footing
Cancelled
09/15/25
RZSteiner
 
 
103 Footing
Reviewed
09/29/25
AEParrish
Footings from line 14 to sub grid N33, and line NA D to NA Q. Highlighted on plans by AEP.
 
103 Footing
Reviewed
10/17/25
RZSteiner
Footings A-D and 1-4
 
103 Footing
Reviewed
11/03/25
RZSteiner
See approved plans for highlighted locations of footings.
 
103 Footing
Reviewed
12/10/25
RZSteiner
Bldg. A pending SPI
 
103 Footing
Cancelled
12/29/25
RZSteiner
 
 
103 Footing
Reviewed
01/15/26
AEParrish
See approved plans for highlighted locations of footings. Sheet S2.3 grid lines P1 - P8, PQ -PJ, dated 1/15/26 AEP, ok pending SPI.
 
103 Footing
Reviewed
02/05/26
RZSteiner
Column foundations sheet 2.3 for location.
 
103 Footing
Denied
02/11/26
RZSteiner
Submit SI to C.O.E. for log ramp footing and wall. Approximate location sheet 2.3 PE-PF and P3-P8. OSSC 107.4
 
103 Footing
Reviewed
03/03/26
AEParrish
South ramp footing ok pending SPI. North ramp footing inspected on 1/15/26 by AEP SI sheets D 36-2401074. Footings on grid lines PJ - PQ and P10 - P15 ( High lighted on plans dated 3/3/26 ).
 
103 Footing
Cancelled
03/18/26
RZSteiner
 
 
103 Footing
Needed
   
 
108 Foundation
Reviewed
05/19/25
RZSteiner
 
 
108 Foundation
Reviewed
06/05/25
RZSteiner
SOG Line 28-37 A to B- Pending SPI
 
108 Foundation
Reviewed
06/09/25
RZSteiner
SOG line 28-37 and A-C
 
108 Foundation
Reviewed
06/13/25
RZSteiner
SOG line 28-45 B.5-E
 
108 Foundation
Reviewed
06/18/25
RZSteiner
SOG 28-45 line and E.7-J
 
108 Foundation
Reviewed
06/25/25
RZSteiner
SOG line 31-45 PJJ-PDD and Line 40-45 =B-B.5
 
108 Foundation
Reviewed
07/02/25
RZSteiner
SOG 28-31 J-S and 31-45 PJJ-S
 
108 Foundation
Reviewed
07/14/25
RZSteiner
SOG A-PH and 19-28
 
108 Foundation
Reviewed
07/17/25
RZSteiner
SOG around S.E. restrooms.
 
108 Foundation
Reviewed
08/01/25
AEParrish
SOG for sorter building, first section S-AK & 42-36, and second section AK-BC & 42-36.
 
108 Foundation
Reviewed
08/12/25
RZSteiner
SOG S. of 16 line and approx 80' west.
 
108 Foundation
Reviewed
08/18/25
RZSteiner
SOG
 
108 Foundation
Reviewed
08/25/25
RZSteiner
Footings on 13-14 line N-X
 
108 Foundation
Reviewed
09/02/25
RZSteiner
SOG 16-28 and NZ-NAJ
 
108 Foundation
Reviewed
09/10/25
RZSteiner
SOG 14-16 and NAK-X
 
108 Foundation
Reviewed
09/15/25
RZSteiner
SOG 16-28 and NAJ-NAQ. SOG N51-16 and NAQ-X
 
108 Foundation
Reviewed
09/22/25
RZSteiner
SOG NAQ-X and N21-28
 
108 Foundation
Reviewed
10/06/25
RZSteiner
SOG rebar for building B
 
108 Foundation
Reviewed
11/17/25
RZSteiner
SOG D-Q and 14-N39
 
108 Foundation
Reviewed
12/01/25
RZSteiner
SOG at 1-N27 and P-NAA
 
108 Foundation
Reviewed
12/09/25
RZSteiner
SOG
 
108 Foundation
Reviewed
12/16/25
RZSteiner
SOG line 1-N27 and D-NAA
 
108 Foundation
Reviewed
12/22/25
RZSteiner
SOG N32-N27 and P-NAA
 
108 Foundation
Reviewed
12/29/25
RZSteiner
SOG for building A
 
108 Foundation
Reviewed
03/03/26
AEParrish
North side ramp walls (infeed ramp) rebar inspection ok pending SPI. Plans for ramp on approved SI, sheets D 36-241074, 1&2.
 
108 Foundation
Reviewed
03/18/26
RZSteiner
Column foundations P11-P16 and PJ-PQ
 
108 Foundation
Reviewed
04/10/26
RZSteiner
2nd ramp wall pending SPI
 
108 Foundation
Cancelled
04/15/26
IVRUser
 
 
108 Foundation
Reviewed
04/16/26
RZSteiner
Ext. SOG at Log ramp.
 
108 Foundation
Reviewed
04/22/26
RZSteiner
Ext. SOG E. side
 
108 Foundation
Reviewed
10/07/26
RZSteiner
N. log ramp slab
 
108 Foundation
Needed
   
 
118 Framing
Reviewed
10/30/26
RZSteiner
Break room. Ned permit for HVAC
 
118 Framing
Denied
11/19/26
RZSteiner
Sumit SI for restrooms/breakroom and mechanical DS-9
 
118 Framing
Needed
   
 
146 Fire Sprinklers
Reviewed
07/16/26
KAHaggas
Rough Sprinkler Inspection for Bldgs E1, E2, G: overhead systems only; piping, supports, bracing, locations ok. Still need hydro tests. See onsite plans showing areas inspected (green).
 
146 Fire Sprinklers
Needed
   
 
147 Alarm Systems
Needed
   
 
153 Water/Hydrant System
Reviewed
03/12/26
ATBrushett
Underground inspection complete portion of pipe inspected marked on the plans. Need thrust blocks and hydrant installed.
 
153 Water/Hydrant System
Reviewed
03/13/26
KAHaggas
Partial underground fire line inspection: depth, bedding, restraints ok, ok to cover as marked on site plans.
 
153 Water/Hydrant System
Reviewed
03/16/26
KAHaggas
Pics provided, ok to cover and continue.
 
153 Water/Hydrant System
Reviewed
03/17/26
KAHaggas
Underground Fire Line from previously installed ductile heading west (see job plans), depth, bedding, restraints ok, ok to cover.
 
153 Water/Hydrant System
Reviewed
03/19/26
KAHaggas
Additional fire line installed, ok to cover, see on site plans.
 
153 Water/Hydrant System
Reviewed
03/19/26
ESPhillips-Meadow
Several sections of 10" underground line verified with multiple thrust blocks. Marked on plans.
 
153 Water/Hydrant System
Cancelled
03/20/26
ESPhillips-Meadow
 
 
153 Water/Hydrant System
Reviewed
03/23/26
ESPhillips-Meadow
underground fire line inspection - see notes on drawing from site inspection
 
153 Water/Hydrant System
Reviewed
03/24/26
ESPhillips-Meadow
80 additional feet of 8" and 10" fire line. Ok to cover.
 
153 Water/Hydrant System
Reviewed
03/31/26
KAHaggas
Underground fire line and thrust blocks inspected, depth, bedding, joints ok, ok to cover; see on site plans.
 
153 Water/Hydrant System
Reviewed
04/08/26
ATBrushett
Tie into existing fire line in the log yard area OK.
 
153 Water/Hydrant System
Reviewed
04/20/26
ATBrushett
3 building stub ins inspected and OK to cover. Need to bag the new hydrants so they are not used
 
153 Water/Hydrant System
Reviewed
06/17/26
KAHaggas
Underground at west of saw bldg, north of sorter ok to cover.
 
153 Water/Hydrant System
Reviewed
06/22/26
KAHaggas
Underground fire lines at northeast corner of site ok to cover; see onsite plans.
 
153 Water/Hydrant System
Reviewed
06/23/26
KAHaggas
underground fire lines on east side ok to cover; see onsite plans.
 
153 Water/Hydrant System
Reviewed
06/24/26
KAHaggas
Underground fire line work; depth, bedding, joints, thrust blocks at east side ok.
 
153 Water/Hydrant System
Reviewed
07/10/26
ESPhillips-Meadow
Fire Line inspection on east side near Keslo St. gate. Installation includes double check assembly and piping. Marked in blue on plans and dated.
 
153 Water/Hydrant System
Reviewed
07/13/26
ATBrushett
Thrust blocks poured near the vault. Tie-ins and FDC still need to be complete
 
153 Water/Hydrant System
Reviewed
07/15/26
KAHaggas
Underground fire line - last sections to complete loop installed; depth, bedding, joint restraints ok, ok to cover.
 
153 Water/Hydrant System
Reviewed
07/17/26
KAHaggas
fdc, last riser, last hydrant all in place; depth, bedding, restraints ok, ok to cover. As of this inspection, all underground piping installed. Need hydrostatic test (200 psi for 2 hours), flush of all the new lines, forward flow/hydrant flow tests.
 
153 Water/Hydrant System
Reviewed
07/29/26
KAHaggas
relocated 10" riser on east side - ok to cover.
 
153 Water/Hydrant System
Reviewed
08/06/26
KAHaggas
Underground fire line system hydrostatic test = Pass.
 
153 Water/Hydrant System
Reviewed
11/12/26
KAHaggas
Flushed underground fire line through 7 riser stub-ins - ok. Pressure/flow looks good for sprinkler demand. Still need to flush fire hydrants and get flow info for fire hydrants. Need Underground Installation Certification submitted to TCE.
 
153 Water/Hydrant System
Needed
   
 
154 Standpipe
Needed
   
 
143 Fire Regulation
Reviewed
03/11/26
ATBrushett
Fire line and the hydrant line on the southwest side are OK to cover except where the thrust blocks are needed.
 
143 Fire Regulation
Not Needed
03/19/26
ESPhillips-Meadow
wrong inspection - refer to hydrant / water inspection
 
143 Fire Regulation
Cancelled
07/16/26
KAHaggas
This was a sprinkler inspection, see Fire Sprinklers entry.
 
150 Landscaping
Needed
   
 
919 Bicycle Parking
Needed
   
 
160 Emerg Egress Light
Needed
   
 
199 Final Building
Needed
   
Electrical
Active
02/11/25
11/14/27
  
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
210 Undergrnd/Slab Elec
Reviewed
04/14/25
SRFitzHenry
see highlighted plans on site
 
210 Undergrnd/Slab Elec
Reviewed
04/17/25
SRFitzHenry
see highlighted print on site
 
210 Undergrnd/Slab Elec
Reviewed
04/24/25
SRFitzHenry
see highlighted plan
 
210 Undergrnd/Slab Elec
Reviewed
05/08/25
SRFitzHenry
see highlighted plans onsite
 
210 Undergrnd/Slab Elec
Reviewed
05/13/25
SRFitzHenry
spoke about high voltage clearances
 
210 Undergrnd/Slab Elec
Reviewed
05/21/25
SRFitzHenry
see highlighted prints on site
 
210 Undergrnd/Slab Elec
Reviewed
06/11/25
SRFitzHenry
see highlighted print onsite
 
210 Undergrnd/Slab Elec
Cancelled
11/03/25
SRFitzHenry
 
 
210 Undergrnd/Slab Elec
Needed
   
 
215 Electrical - Feeder
Needed
   
 
217 Electrical Service
Approved
10/30/25
SRFitzHenry
blatchly lane.
 
213 Bonding/Grounding
Reviewed
06/11/25
SRFitzHenry
see plan onsite
 
213 Bonding/Grounding
Reviewed
08/27/25
SRFitzHenry
see plans on site, (5) 4/0 at footing this date
 
213 Bonding/Grounding
Needed
   
 
220 Rough Electrical
Reviewed
10/29/26
SRFitzHenry
5 MCC rooms and the lunch room ok to cover
 
220 Rough Electrical
Needed
   
 
230 Limited Energy
Needed
   
 
299 Final Electrical
Needed
   
Fire
Active
01/10/25
11/14/27
  
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
849 Final Fire
Needed
   
Plumbing
Active
01/10/25
11/14/27
  
 
Inspection
Result
 
Inspected
Inspector
Comment
 
 
402 Sanitary Sewer - Private
Reviewed
05/18/26
JSHemmele
11/2" sch. 80 pvc running from tank on the SE corner of building along fence running east/west. needs to be tested. 2" sch. 80 pvc running east/west connecting existing line. JSH
 
402 Sanitary Sewer - Private
Reviewed
06/02/26
JSHemmele
2" sch. 80 pvc running east/west on the southside of furthest building then turning north running under first building through sleeve. JSH
 
402 Sanitary Sewer - Private
Reviewed
06/08/26
JSHemmele
2-2" sch 80 pvc ( 1- existing, 1-new) running from cell tower to septic tank. connection to come. JSH
 
402 Sanitary Sewer - Private
Reviewed
06/09/26
JSHemmele
Connection to septic tank is done. ok to cover. JSH
 
402 Sanitary Sewer - Private
Reviewed
06/25/26
JSHemmele
2" sch 80 pvc ran to sewer ejector on the west of building, 11/2" sch 80 pvc from there to sewer ejector on the NW of building. ok to cover. JSH
 
402 Sanitary Sewer - Private
Reviewed
07/06/26
JSHemmele
11/2" and 2" sch 80 pvc on test. JSH
 
402 Sanitary Sewer - Private
Needed
   
 
403 Storm Sewer - Private
Reviewed
02/11/25
SEKelley
3-20’ sticks of 24” CPE with tracer wire and a 12” tee to pick up a future catch basin. All going to a future pour in place MH.
 
403 Storm Sewer - Private
Reviewed
02/12/25
SEKelley
5-20’ sticks of 24” CPE with tracer wire, okay to cover.
 
403 Storm Sewer - Private
Cancelled
02/13/25
JRLaCasse
Per Jason Johnson of Wildish
 
403 Storm Sewer - Private
Cancelled
02/14/25
JRLaCasse
per jason of wildish via text
 
403 Storm Sewer - Private
Reviewed
02/18/25
SEKelley
5-20’ sticks of 24” CPE with tracer wire okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/19/25
SEKelley
2-9’ sticks of 8” 3034 connected to two concrete catch basins via sand collars with tracer wire, okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/21/25
SEKelley
100’ of 8” 3034 with tracer wire picking up drainage from a concrete catch basin connected via sand collar, okay to cover
 
403 Storm Sewer - Private
Reviewed
02/21/25
SEKelley
12” Inserta tee with 12’ of 12” cpe with tracer wire to serve a catch basin into 48” cpe mainline. Okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/24/25
SEKelley
1-20’ stick of 24” cpe with tracer wire connected to a 48” Cast in Place MH, okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/25/25
SEKelley
7-20’ sticks of 24” CPE with tracer wire connected to a 48” MH, okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/26/25
SEKelley
5-20’ sticks of 24” CPE with tracer wire, okay to cover.
 
403 Storm Sewer - Private
Reviewed
02/27/25
SEKelley
Continuation of 24" CPE with tracer wire to manhole base. Tee installed and 3 catch basins installed, ok to cover.
 
403 Storm Sewer - Private
Reviewed
02/28/25
SEKelley
5 sticks of 24" CPE with tracer wire, ok to cover.
 
403 Storm Sewer - Private
Reviewed
03/03/25
SEKelley
3-20’ sticks of 24” CPE with tracer wire with connection into a Cast in Place MH, okay to cover.
 
403 Storm Sewer - Private
Reviewed
03/04/25
SEKelley
7-20’ sticks of 12” cpe with tracer wire connected to new MH and one 12” by 12” tee per plan.
 
403 Storm Sewer - Private
Reviewed
03/05/25
SEKelley
140’ of 12” cpe with tracer wire and a 12” by 12” tee, picking up drainage from a concrete CB, per plan no cleanout’s. okay to cover.
 
403 Storm Sewer - Private
Reviewed
03/06/25
SEKelley
10’ of 12” cpe lateral grouted into square concrete CB with tracer wire, two other CB’s have 12” cpe laterals grouted into them with tracer wire, okay to cover.
 
403 Storm Sewer - Private
Reviewed
04/22/25
RC Kennedy
24-05904-01-Reviewed-Storm, 120’ of 24” CPE with tracer wire from existing MH to new MH, 60’ of 24” CPE with tracer wire, upstream of new MH, okay to cover.
 
403 Storm Sewer - Private
Reviewed
04/23/25
RC Kennedy
24-05904-01-Storm-Reviewed, Pg. C104, 130’ of 24” CPE with tracer wire, MH set and connected, okay to cover
 
403 Storm Sewer - Private
Reviewed
04/24/25
RC Kennedy
24-05904-01-Storm -Reviewed, Pg C104, 170’ of 24” CPE with tracer wire connected to MH, 57’ of 12” CPE serving a concrete CB connected into MH.
 
403 Storm Sewer - Private
Reviewed
04/25/25
SEKelley
100’ of 18” CPE with tracer wire from MH to serve a CB. 20’ of 24” CPE with tracer wire connecting to a MH, okay to cover all.
 
403 Storm Sewer - Private
Reviewed
04/28/25
RC Kennedy
24-05904-01-Reviewed-storm, 20’ of 18” CPE with tracer wire and a 18” by 4” c/o, okay to cover.
 
403 Storm Sewer - Private
Reviewed
04/29/25
RC Kennedy
24-05904-01-Storm-Reviewed, Pg. C103, 2-MH cones and 2-flat top lids installed on 4-MH’s, 93’ of 18” CPE serving CB with tracer wire, 57’ of 12” CPE w/tracer wire, CB to MH, okay to cover.
 
403 Storm Sewer - Private
Reviewed
04/30/25
RC Kennedy
24-05904-01-Storm-Reviewed, 2-8” inserta tee’s into 24” CPE with 15’ of 8” 3034 south side of new building with tracer wire, 15’ of 8” CPE with tracer wire connected to MH and new CB. Okay to cover.
 
403 Storm Sewer - Private
Reviewed
05/01/25
RC Kennedy
24-05904-01-Storm-Reviewed, 9-8” inserta tee’s into 24” and 48” CPE with a total of 277” of 8” 3034 with tracer wire, may cover
 
403 Storm Sewer - Private
Reviewed
03/10/26
JSHemmele
6- 8" rain drains along the S/E of building. JSH
 
403 Storm Sewer - Private
Reviewed
03/26/26
JSHemmele
5- 8" rain drains along the SE corner of building. One length of 12" running out of MH towards CB on the NW corner of building. JSH
 
403 Storm Sewer - Private
Reviewed
03/27/26
RC Kennedy
12" from concrete area drain to manhole on Northwest side of new building. RCK
 
403 Storm Sewer - Private
Info Only
03/31/26
JSHemmele
 
 
403 Storm Sewer - Private
Reviewed
04/07/26
JSHemmele
Replaced 90's on the SE side of building. Ok to cover. JSH
 
403 Storm Sewer - Private
Reviewed
04/24/26
JSHemmele
5- 8" raindrains on the SW end of building. JSH
 
403 Storm Sewer - Private
Cancelled
05/18/26
JSHemmele
Needed sanitary sewer. JSH
 
403 Storm Sewer - Private
Reviewed
07/07/26
JSHemmele
5- rain drains on the north side of the sw building. 90's and c/o's to come. JSH
 
403 Storm Sewer - Private
Reviewed
07/13/26
JSHemmele
5- storm lines 90'ed up on the northside of SW building. ok to cover. JSH
 
403 Storm Sewer - Private
Needed
   
 
318 Under Floor Plumb
Reviewed
05/09/25
RC Kennedy
1" PEX running West to East on South conveyer line. Turning North. Air test ok, piping on interior of foundation. RCK
 
318 Under Floor Plumb
Reviewed
05/27/25
RC Kennedy
2" PEX serving South RR, air test ok. RCK
 
318 Under Floor Plumb
Reviewed
07/10/25
RC Kennedy
Rest room break room Southeast side, G.L. 41-45 and -B-A. Test ok, ok to cover. 4" waste stub to rest room on West side, G.L. 28-N Pictures to come. RCK
 
318 Under Floor Plumb
Reviewed
07/18/25
RC Kennedy
Required pictures received, 7/18/25. RCK
 
318 Under Floor Plumb
Reviewed
08/22/25
SEKelley
Restrooms at Grid Lines N and 28, ok to cover.
 
318 Under Floor Plumb
Reviewed
09/05/25
RC Kennedy
Rest room break room Southeast side, G.L. 41-45 and -B-A, pictures received of trap primer lines, floor drains, pipe wrapped for concrete pour. RCK
 
318 Under Floor Plumb
Reviewed
12/05/25
JSHemmele
Restrooms and mop sink. grid lines D-6. JSH
 
318 Under Floor Plumb
Needed
   
 
320 Rough Plumbing
Needed
   
 
325 Water Service
Reviewed
10/06/26
JSHemmele
2" pex with tracer wire on air test. ok to cover. Meter connection and static pressure check to come. JSH
 
325 Water Service
Needed
   
 
399 Final Plumbing
Needed
   
To request an inspection go to https://pdd.eugene-or.gov/BuildingPermits/InspectionLogin.
For more information call 541-682-5283.
FEES
Fees
Total Due
Amount Paid
Paid Date
Amount Due
Application
$26,400.00
$26,400.00
 
$0.00
Bethel Const Excise Tax, Commercial
$26,400.00
$26,400.00
01/09/25
$0.00
Miscellaneous Admin, State
$0.00
$0.00
01/09/25
$0.00
Building
$352,172.76
$352,172.76
 
$0.00
Building Plan Check per Applicant Value
$53,356.63
$53,356.63
08/23/24
$0.00
Supplemental Plan Review, Bldg
$1,148.00
$1,148.00
01/09/25
$0.00
Supplemental Plan Review, Bldg
$287.00
$287.00
02/21/25
$0.00
Supplemental Plan Review, Bldg
$114.80
$114.80
03/24/26
$0.00
Supplemental Plan Review, Bldg
$287.00
$287.00
08/06/26
$0.00
Supplemental Plan Review, Bldg
$114.80
$114.80
10/02/26
$0.00
Supplemental Plan Check, Str. Eng.
$688.80
$688.80
01/09/25
$0.00
Supplemental Plan Check, Str. Eng.
$344.40
$344.40
01/09/25
$0.00
Supplemental Plan Check, Str. Eng.
$229.60
$229.60
03/10/25
$0.00
Supplemental Plan Check, Str. Eng.
$344.40
$344.40
06/10/25
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
06/25/25
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
07/23/25
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
08/01/25
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
03/02/26
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
03/24/26
$0.00
Supplemental Plan Check, Str. Eng.
$459.20
$459.20
05/22/26
$0.00
Supplemental Plan Check, Str. Eng.
$229.60
$229.60
10/02/26
$0.00
Supplemental Plan Check, Str. Eng.
$57.40
$57.40
11/19/26
$0.00
SI - Fire/Life Safety PC Added Value
$2,005.18
$2,005.18
03/31/25
$0.00
Fire/Life Safety Plan Check
$47,009.37
$47,009.37
01/09/25
$0.00
Fire Systems Plan Check Fee - Sprinklers
$4,566.65
$4,566.65
05/20/25
$0.00
Adjusted Building Plan Check
$23,033.59
$23,033.59
01/09/25
$0.00
SI - Bldg Plan Check for Added Value
$3,258.41
$3,258.41
03/31/25
$0.00
Deferred Submittal Plan Check
$416.14
$416.14
05/20/25
$0.00
Building Permit Fee per Bldg Div Value
$117,523.42
$117,523.42
01/09/25
$0.00
SI - Building Permit for Added Value
$5,012.94
$5,012.94
03/31/25
$0.00
Fire System Permit Fee - Sprinklers
$7,025.62
$7,025.62
05/20/25
$0.00
Inspection Outside Normal Work Hours
$229.60
$229.60
10/21/25
$0.00
Zoning Plan Check
$52,885.54
$52,885.54
01/09/25
$0.00
Supplemental Plan Review, Zoning
$114.80
$114.80
01/09/25
$0.00
Supplemental Plan Review, Zoning
$114.80
$114.80
01/09/25
$0.00
Supplemental Plan Review, Zoning
$34.44
$34.44
03/10/25
$0.00
Supplemental Plan Review, Zoning
$11.48
$11.48
03/31/25
$0.00
Zoning Inspection
$229.60
$229.60
01/09/25
$0.00
SI - Zoning Plan Check for Added Value
$2,255.82
$2,255.82
03/31/25
$0.00
State Surcharge, Structural
$14,557.00
$14,557.00
01/09/25
$0.00
State Surcharge, Structural
$601.51
$601.51
03/31/25
$0.00
State Surcharge, Structural
$843.07
$843.07
05/20/25
$0.00
State Surcharge, Structural
$27.55
$27.55
10/21/25
$0.00
Building Technology Admin Fee, Local
$4,861.85
$4,861.85
01/09/25
$0.00
Building Technology Admin Fee, Local
$5.74
$5.74
02/21/25
$0.00
Building Technology Admin Fee, Local
$5.28
$5.28
03/10/25
$0.00
Building Technology Admin Fee, Local
$250.88
$250.88
03/31/25
$0.00
Building Technology Admin Fee, Local
$240.17
$240.17
05/20/25
$0.00
Building Technology Admin Fee, Local
$6.89
$6.89
06/10/25
$0.00
Building Technology Admin Fee, Local
$1.15
$1.15
06/25/25
$0.00
Building Technology Admin Fee, Local
$1.15
$1.15
07/23/25
$0.00
Building Technology Admin Fee, Local
$1.15
$1.15
08/01/25
$0.00
Building Technology Admin Fee, Local
$4.59
$4.59
10/21/25
$0.00
Building Technology Admin Fee, Local
$1.15
$1.15
03/02/26
$0.00
Building Technology Admin Fee, Local
$3.44
$3.44
03/24/26
$0.00
Building Technology Admin Fee, Local
$9.18
$9.18
05/22/26
$0.00
Building Technology Admin Fee, Local
$5.74
$5.74
08/06/26
$0.00
Building Technology Admin Fee, Local
$6.89
$6.89
10/02/26
$0.00
Building Technology Admin Fee, Local
$1.15
$1.15
11/19/26
$0.00
Building Plan Check Admin
$3,386.52
$3,386.52
01/09/25
$0.00
Building Plan Check Admin
$0.36
$0.36
03/31/25
$0.00
Building Plan Check Admin
$0.00
$0.00
 
$0.00
Building Admin Fee, State
$3,674.68
$3,674.68
01/09/25
$0.00
Building Admin Fee, State
($0.36)
($0.36)
03/31/25
$0.00
Electrical
$30,987.60
$30,987.60
 
$0.00
Electric Plan Check
$3,880.26
$3,880.26
02/10/25
$0.00
200 amps or less
$267.80
$267.80
02/10/25
$0.00
201 to 400 amps
$7,374.50
$7,374.50
02/10/25
$0.00
601 to 1000 amps
$0.00
$0.00
 
$0.00
Over 1000 amps or volts
$3,012.00
$3,012.00
02/10/25
$0.00
Over 1000 amps or volts
$9,036.00
$9,036.00
05/15/25
$0.00
Branch Circuits w/ Feeder or Service
$432.15
$432.15
02/10/25
$0.00
Branch Circuits w/ Feeder or Service
$3,587.85
$3,587.85
11/11/25
$0.00
State Surcharge, Electrical
$1,330.37
$1,330.37
02/10/25
$0.00
State Surcharge, Electrical
$1,084.32
$1,084.32
05/15/25
$0.00
State Surcharge, Electrical
$430.54
$430.54
11/11/25
$0.00
Electric Technology Admin Fee, Local
$299.33
$299.33
02/10/25
$0.00
Electric Technology Admin Fee, Local
$180.72
$180.72
05/15/25
$0.00
Electric Technology Admin Fee, Local
$71.76
$71.76
11/11/25
$0.00
Electric Plan Check Admin
$0.00
$0.00
 
$0.00
Fire
$18,742.78
$18,742.78
 
$0.00
Fire Plan Check
$17,628.45
$17,628.45
01/09/25
$0.00
Supplemental Plan Review, Fire
$57.40
$57.40
01/09/25
$0.00
Supplemental Plan Review, Fire
$114.80
$114.80
02/21/25
$0.00
Private Water/Hydrant Systems (2 insps)
$454.75
$454.75
03/02/26
$0.00
Reinspection, Fire
$114.80
$114.80
03/02/26
$0.00
Fire Technology Admin Fee, Local
$353.72
$353.72
01/09/25
$0.00
Fire Technology Admin Fee, Local
$2.30
$2.30
02/21/25
$0.00
Fire Technology Admin Fee, Local
$11.39
$11.39
03/02/26
$0.00
Fire Plan Check Admin
$5.17
$5.17
01/09/25
$0.00
Fire Plan Check Admin
$0.00
$0.00
 
$0.00
Plumbing
$4,377.82
$4,377.82
 
$0.00
Plumbing Fixtures
$607.20
$607.20
01/09/25
$0.00
Storm Sewer Footage
$2,584.60
$2,584.60
01/09/25
$0.00
Water Service Footage
$335.50
$335.50
01/09/25
$0.00
State Surcharge, Plumbing
$462.51
$462.51
01/09/25
$0.00
Plumbing Technology Admin Fee, Local
$70.55
$70.55
01/09/25
$0.00
Plumbing Plan Check Admin
$0.00
$0.00
01/09/25
$0.00
Plumbing Admin Fee, State
$317.46
$317.46
01/09/25
$0.00
Public Works
$1,491.34
$1,491.34
 
$0.00
PW Plan Check, New Commercial
$1,176.00
$1,176.00
01/09/25
$0.00
Supplemental Plan Review, Public Works
$114.80
$114.80
01/09/25
$0.00
Supplemental Plan Review, Public Works
$57.40
$57.40
03/10/25
$0.00
PW Technology Admin Fee, Local
$25.82
$25.82
01/09/25
$0.00
PW Technology Admin Fee, Local
$1.15
$1.15
03/10/25
$0.00
PW Plan Check Admin
$116.17
$116.17
01/09/25
$0.00
PW Plan Check Admin
$0.00
$0.00
 
$0.00
Total All Fees
$434,172.30
$434,172.30
 
$0.00
Page 1 of 1
Date: 11/27/2026